Description
The power supply is factory preset at the customer specified output voltage between 11 and 14V DC (usually 13.8V DC).
Mains input is via a 3-pin plug and flex; output terminals for + and – connections are provided outside the case. A battery trickle terminal is also provided, although the main output can be directly connected to a battery.
Electronic limit can be disabled for large peak loads > 10A (e.g radio transmitters, motors…etc).
Installation
The power supply should be installed in a well ventilated area and not enclosed where excessive heat build up can occur. Do not install or mount above any hot air discharge/air-conditioner/radiator or similar equipment. Mounting outside or in a wet/damp environment is also not recommended.
Batteries
Sealed and open lead acid batteries can be charged. Please specify nominal output float voltage and size of battery when ordering.
Specifications
| Output Ripple Voltage @ Full Load | < 0.3% |
|---|---|
| Load Regulation (Zero to Full Load) | < 3.0% |
| Line Regulation (220-240V) @ Full load | < 0.1% |
| Electronic Circuit Current Limit | 10.2A DC (adjustable to 12A max) @ 0-14V DC output |
| Short Circuit Protection Duration | Indefinite |
| Power Factor @ Full Load, 200V AC Input | > 0.99 |
| Input Fuse | 2A Slow Blow 250V AC internally accessible |
| Thermal Protection | Internal protection circuitry on board-fan cooled |
| Voltage limit indication | Green LED |
| Current limit Indication | Red LED |