Description
The power supply can be used as a sealed lead acid battery charger with a maximum output current of 3.1A continuous. No adjustments are required.
Installation
The power supply should be installed in a well ventilated area and not enclosed where excessive heat build up can occur. Do not install or mount above any hot air discharge/air-conditioner/radiator or similar equipment. Mounting outside or in a wet/damp environment is also not recommended.
Specifications
| Output Ripple Voltage @ Full Load | < 0.1% |
|---|---|
| Load Regulation (Zero to Full Load) | < 2.0% |
| Line Regulation (220-240V) @ Full load | < 0.1% |
| Circuit Current Limit (Adjustable) | 3.0A DC (6 – 14V DC) |